IoTerrarium

The world's first comprehensive IoT terrarium controller with integrated multi-level safety systems, intelligent LED diagnostics, and professional-grade environmental monitoring for reptile habitats.

Experience Live Demo

Revolutionary Features

Advanced Failsafe System

Multi-level safety protocols with automatic device shutdown, sensor staleness detection, effectiveness monitoring, and duty cycle limits. No automatic resets - every fault requires manual review.

Intelligent LED Diagnostics

Smart diagnostic LED system with 5 distinct error patterns: communication errors, sensor failures, configuration issues, failsafe triggers, and normal operation indication.

Dual Temperature Monitoring

Precise ambient temperature control with AHT20 sensor plus dedicated DS18B20 probe for cold zone monitoring. Moving average filtering for stable readings.

Tasmota Integration

Professional smart plug control via Tasmota firmware with automatic IP configuration, communication monitoring, and safety disconnection protocols.

Professional Web Interface

Modern responsive web dashboard with real-time monitoring, configuration management, diagnostic tools, and comprehensive safety parameter control.

Programmable Timer System

Advanced lighting control with configurable ON/OFF cycles, manual pulse controls, and automatic day/night transitions for optimal reptile circadian rhythms.

Technical Specifications

Controller Hardware

Microcontroller ESP32 DevKit
Operating Voltage 5V ±5%
Power Consumption ≤300mA
WiFi Standard 802.11 b/g/n

Sensor Capabilities

Temperature Range -40°C to +85°C
Temperature Accuracy ±0.3°C
Humidity Range 0-100% RH
Humidity Accuracy ±2% RH

Control Parameters

Temperature Hysteresis 1.0°C
Humidity Hysteresis 3.0%
Min ON/OFF Time 60 seconds
Sensor Read Interval 30 seconds

Network Configuration

Access Point SSID RettilarioConfig
Controller IP 192.168.4.1
Device Range .10-.12
Communication Protocol HTTP REST

Multi-Level Safety System

Emergency Cutoff

Immediate shutdown if temperature/humidity exceed critical thresholds

Effectiveness Monitoring

Automatic fault detection if devices don't produce expected changes

Maximum Runtime Protection

Prevents continuous operation beyond safe time limits

Duty Cycle Limiting

Restricts total operating time per hour to prevent system stress

Sensor Staleness Detection

System shutdown if sensor data becomes outdated or unreliable

Communication Monitoring

Automatic error detection for offline or unreachable devices

Live System Status

Real-Time Environmental Control

Ambient Temperature
28.3°C
Humidity Level
67%
Cold Zone Temperature
23.1°C
System Status
OPTIMAL

All systems operational. Heater: AUTO | Humidifier: AUTO | Lighting: TIMER ACTIVE